OIL & GAS DIVISION


We act as a support for our customer to improve and maintain their industrial plan activities. We deliver our products and services for Refinery & Exploration... Read More

PULP & PAPER DIVISION


We act as a support for our customer to improve and maintain their industrial plan activities. We deliver our products and servies for Pulp & Paper Mills Industrial Process... Read More

PHARMACEUTICAL, FOOD & BEVERANGE AND PERSONAL CARE DIVISION


We act as a support for our customer to process, heat, cool, separate, transport and... Read More

PRODUCT PULP & PAPER


Lights

Gas Insulated Switchgear

  • Rated Current : 4000A
  • Rated Breaking : 50kA
  • Rated Making : 130kA
  • Standard : IEC 62271-100 / IEC 62271-203 / IEC 62271-102
Lights

Power Transformer

  • Standard: IEC 60076 / ANSI (IEEE) C57
  • Installation Location : Outdoor / Indoor
  • Frequency [Hz] : 50/60
  • Winding Temp. Rise[K] : 65 K
  • Cooling Method : ONAN / ONAF / ODAF
  • Application : GSU/AUTO/Substation
  • Voltage (kV) : Up to 550kV
  • Capacity (MVA) : Up to 800MVA
  • Annual Production : 15,000 MVA
Lights

Transmission and Substation

  1. System Engineering
    • Feasibility Study
    • System Design
    • System Analysis
  2. Project and Safety Management
  3. Manufacturing
    • HV Switchgear (GIS/AIS)
    • Power Transformer
    • MV/LV Switchgear
    • AC/DC System
    • Earthing & Bonding System
    • Protection & Control
    • Lightening
    • Fire protection
  4. Installation
  5. Civil work & Construction
  6. Test and Commissioning

Lights

High Voltage Direct Current

  • Converter Transformer
  • 12 Pulse Valve
  • Control & Protection
  • AC Dielectric : 500 kV
  • DC Dielectric : 1500 kV
  • Light Impulse : 2000 kV
Lights

Medium Voltage Solution

  • Rated Frequency (Hz) : 50/60Hz
  • Rated Current (A) : ~3150A
  • Rated Power Frequency withstand voltage : 50kV
  • BIL (kV[1.2kx50us]) : 125kV
  • Rated short-time withstand current (kA/s) : 25-40kA/3S
  • Internal Arc withstand current(kA/s) : 25kA/1S
  • Standard : IEC 62271-200, ANSI
Lights

Low Voltage

  • RMU
  • 12KV, 17.5kV, 24KV
  • 630A
  • 21kA(3s)
  • Extensible, Non-Extensible
  • IEC62271-1~200

Lights

LV Application/ SIS

  • 25.8KV
  • 2000A(Single), 4000A(Double)
  • 25kA (3s)
  • Epoxy resin Insulation
  • IEC62271-200
Lights

LV Application/ Bus duct

  • Up to 1000V
  • 630~6000A (Al), 630~7500A (Cu
  • 220kA(1s)
  • IEC
Lights

LV Application/ SWGR

  • 600V
  • 630~5000A
  • 80kA(1s)
  • IEC